Overview#
The NXP DDR Tool is a Visual Studio Code extension that simplifies DDR memory configuration and validation for NXP microprocessor unit (MPU) devices. With an intuitive graphical interface, developers can easily configure memory parameters, validate settings on real hardware, and generate configurations—all without leaving VS Code.
Note: This user guide is for NXP DDR Tool version 26.11. For the latest updates and information, check the extension marketplace page.
Note: The software is subject to the NXP software license agreement.
Key features#
DDR memory configuration and validation for NXP MPU devices
Support for LPDDR4, LPDDR4X and LPDDR5 memory types
Processor data (supported processors, memory types, part numbers, and presets) is downloaded from the NXP cloud repository, so new devices and presets are available without a new extension version
Preset-based configuration for NXP boards
MVI (Multi-Vendor Initiative) configurations for memory part numbers from different vendors tested by NXP, with a DQ/CA mapping check warning
Guided, step-by-step configuration workflow (Configuration → Connection → Tests) in a single unified panel
Real-time, field-level validation with inline error messages
Configuration editor toolbar (reset to default, validation status, filter, expand/collapse all)
Automatic C code generation with a live Code Preview (change indicators, diff view, code folding, manual editing, and export)
Import and save capability
Reset configuration to return to a clean processor selection
Board detection with COM port and USB HID selection
Connection testing against the connected target (required before running tests)
Test execution on connected hardware — run an individual test, run all tests, or select the tests to run, and cancel a running test or test session at any time
Test pattern settings for the tests that write a data pattern, with an editable default pattern or a random pattern that can be regenerated
ODT and driver strength optimization tests (Read/Write) with a live pass/fail result map to help you select the settings with the best signal margins, and an option to apply the settings of a selected cell to the configuration
Diagnostics (VTSA) Rx/Tx eye tests with per-lane eye diagrams and an All Lanes Summary that identifies the worst DQ lanes for eye width and height
Test logging with per-run log files and a summary report
DDR Tool Logs panel with a dedicated log viewer: filter by level and source, search with match navigation, go to the top or bottom, pause live tailing, clear the view, and export the logs to a file
Part details card for the selected part number, with silicon revision selection for devices with multiple revisions and boot image (ELE container) details of the revision in use
Live DDR validation report that sums up the configuration, the PHY settings, the test results, the ODT mapping, the eye diagrams, and the logs, with an overall final result. You can export it as a PDF file or as a standalone HTML file
Toolchain management (install, uninstall, reset, and check for updates)
GitHub Copilot integration (requires VS Code 1.99+) — Configure the processor, memory type, part number, and presets, and edit configuration parameters, from the Copilot Chat panel using natural language or a guided wizard. This feature is experimental.
System requirements#
Supported operating systems#
Windows 11 (64-bit)
Ubuntu 24.04 (64-bit)
Ubuntu 26.04 (64-bit)
Software requirements#
Visual Studio Code (the latest version is recommended)
Python environment (the tool configures this automatically)
Hardware support#
i.MX 91 series
i.MX 93 series
i.MX 93W series
i.MX 937 series
i.MX 943 series
i.MX 95 series
i.MX 952 series
i.MX 96F1 series
ARA260 series
Supported memory types#
LPDDR4
LPDDR4X
LPDDR5
Installation#
Installing the extension#
Open Visual Studio Code
Go to the Extensions view (Ctrl+Shift+X)
Search for “DDR Tool for VS Code”
Click Install
Accepting the DDR Tool Notice#
Before the tool can be used, you must read and accept the DDR Tool Notice. Acceptance is required again after each new extension version is installed.
On first use (and after installing a new extension version), the Welcome view shows a Review and Accept Notice prompt.

Read the notice and accept it to unlock the tool interface.

You can review the notice again at any time from the View Disclaimer entry in the Welcome panel, or from the Command Palette (Ctrl+Shift+P) by running Help: View Disclaimer.

Setting up the Python environment#
After you accept the DDR Tool Notice, the Welcome view shows the Install Toolchain button.

To set up the preconfigured Python environment automatically, click the button.
Wait for the installation to complete (this process may take several minutes).
After the installation is complete, the tool interface is fully loaded and ready to use. The Welcome view then shows the Manage Toolchains, Reports, Documentation, and View Disclaimer entries (see Welcome Panel for details).
Getting started#
Working with DDR Tool#
1. Open VS Code#
Launch Visual Studio Code on your system
2. Access the DDR Tool#
Look for the NXP DDR Tool icon in the Activity Bar
Or open the Command Palette (Ctrl+Shift+P) and search for “DDR Tool”
![]()
3. Select the target processor and memory type#
The processor data is downloaded from the NXP online (cloud) repository. This data includes the list of supported processors and their memory types, part numbers, and presets. Because the data comes from the cloud, NXP can add new processors, part numbers, and presets, or update existing ones, without a new version of the extension.
Note: An internet connection is required to download the processor data.
Select a processor from the supported devices list, and then download the processor data from the cloud. When the download is complete, the memory types, part numbers, and presets for that processor are available for selection.

Select the memory type available for that processor (LPDDR4, LPDDR4X, or LPDDR5).
Choose a part number from the available options. To show or hide the details of the selected part, use the info icon next to Select Part Number (see Part details and silicon revision).
Based on your selections, a preset configuration is assigned: if only one preset is available, it is automatically applied; if several presets are available, select the one that matches your design.

Part details and silicon revision:
The part details card shows the information decoded from the selected part number and the silicon revision that the tool uses for the boot image.
Show / hide the part details: Click the info icon (a chip with an “i”) next to Select Part Number. Its tooltip reads Show part details or Hide part details. Click it again, click the close (X) button of the card, or press Esc to hide the card. You can also open the card from the processor chip in the summary bar of the Select Configuration subsection. The chip shows the processor and the silicon revision in use, for example
MIMX95 · B0.Header: shows the part number. Click the Copy part details button to copy the processor, part number, silicon revision (and its source), and ELE container file to the clipboard.
Badges: shows the Processor, Package, and number of Cores. For a device with only one silicon revision, a Rev badge shows that revision.

Selecting the silicon revision:
If the processor has several silicon revisions, the card shows a Silicon revision selector with one button for each revision, and the info icon has a dot on it.
By default, the tool uses the revision decoded from the part number.
To use another revision, click it or use the arrow keys to move between revisions. The card then shows Manual below the selector, and the tooltip of the info icon indicates that the revision was set manually.
To go back to the revision of the part number, click Reset to Default, or select that revision again.
If the tool cannot decode the revision from the part number, it uses the first supported revision and shows Default below the selector.
The tool uses the selected revision for the connection to the target and for the test runs. If the tool cannot change the revision, it shows an error message and keeps the previous revision.
While a test is running, the configuration is locked. You can open and read the card, but you cannot change the revision.
![]()
Boot image details:
Click Boot image details to expand or collapse this section (it is collapsed by default). It shows the ELE container file used in the boot image for the silicon revision in use.
When you select another silicon revision, the tool updates the ELE container file for that revision.
The section is not shown when the processor data has no ELE container.

MVI configurations:
Besides the default configurations for NXP boards, the tool can also show the MVI (Multi-Vendor Initiative) configurations. MVI configurations are default configurations for memory part numbers from different memory vendors that NXP has tested with a specific processor.
When the MVI configurations are shown, you can select an MVI configuration for the memory part number that is used on your board.
The MVI configurations that are available depend on the selected processor and memory type. Only the memory part numbers that NXP has tested with that processor are listed.
After you select an MVI configuration, you can use and edit it in the same way as an NXP board preset (see the next step).

DQ/CA mapping warning:
An MVI configuration contains the memory settings for the selected part number, but the DQ and CA bus pin mapping is taken from the NXP board. When you select an MVI configuration, the tool shows a warning that tells you to check that the DQ/CA mapping is correct for your board.
If your board routing is the same as the NXP board, you can keep the default mapping.
If your board routing is different, update the DQ and CA bus pin mapping before you generate the code or run tests on the target (see Board bus configuration).

4. Use a preset or create a custom configuration#
Presets provide validated configurations for specific NXP board setups and serve as the starting point for your configuration.
You can use the assigned preset as-is, switch to a different preset at any time, or adjust its parameters to create a custom configuration.

The DDR configuration is organized into collapsible sections that you edit in the configuration editor. Fields are validated as you edit them, and some values are read-only because they are recomputed automatically. When a value is invalid or inconsistent with other settings, the affected field is flagged inline with an error message describing the problem (for example, “End address must be higher than the start address!”). Resolve the flagged fields to make the configuration valid again.
The configuration editor provides a toolbar to help you work with the settings:
Modified badge: shows how many settings differ from the preset defaults; hover it to see the list of modified fields.
Reset to Default: resets all settings back to the preset defaults. This button is disabled when there are no modifications.
Validation status: displays Valid when the configuration is correct, or the number of Error(s) when there are validation problems.
Filter settings: type in the filter box to show only the settings that match your text; a message is shown when nothing matches, and the box can be cleared.
Expand All / Collapse All: expands or collapses all configuration sections at once.
Collapse Code Preview / Expand Code Preview: the editor uses a split-pane layout with a code preview alongside the settings. Use this toggle to hide the code preview to get more room for the settings, or show it again to see the generated code as you edit.
A Scroll to top button is also available to quickly return to the top of the configuration when you have scrolled down.
4.1. Memory configuration#
Define the memory device and how it is attached to the SoC, including data rate, number of ranks and channels, and organization settings, along with mode-register settings.

4.2. DDR controller#
Configure the DDR controller behavior, grouped into sub-sections such as error handling, chip selects, refresh, and miscellaneous controller options.

4.3. Board bus configuration#
The DQ and CA bus pin mapping is package-dependent and is loaded from the selected preset. Adjust it only if your board routing differs from the reference design.

4.4. Saving configuration changes#

5. C code generation and Code Preview#
The configuration editor shows a Code Preview alongside the settings that displays the C source generated from your current configuration. It updates as you edit the configuration, and it can be hidden or shown with the Collapse Code Preview / Expand Code Preview toggle.
The Code Preview provides the following functionality:
Change indicators: lines that differ from the previously generated code are marked as Added, Modified, or Deleted. A change-overview ruler along the side highlights where the changes are; click a mark to jump to that line.

Show changes only / Show the whole file: switch between the full generated file and an inline diff that lists only the changed regions (compared to the previously generated code).

Collapse all structs / Expand all structs: fold or unfold all top-level structures at once. You can also collapse or expand individual structures using the fold toggles in the gutter.

Edit code manually / Exit edit mode: switch the preview into an editable mode so you can change the generated code by hand.
Manual editing badge: while editing, a Manual editing enabled badge is shown. Once you make changes, the badge changes to Manual edits applied — code may not reflect the current configuration.

Discard edits: revert any manual edits and return to the generated code.
Export generated code: save the currently displayed code (including any manual edits) to a file. A save dialog opens with a default file name and a C files (.c/.h) filter so you can choose the location and name. After the file is written, a notification shows the full path with a Show in Folder action to reveal it. If there is no generated code yet, a warning is shown instead.
Scroll to top: return to the top of the preview.

Collapse Code Preview / Expand Code Preview — the editor uses a split-pane layout with the Code Preview alongside the settings. Use this toggle to hide the Code Preview and give the settings more room, or show it again to see the generated code as you edit.

The code is always generated automatically: it is produced when a preset is selected and regenerated whenever the configuration changes.
If the code cannot be generated — for example, because the current configuration is invalid or produces bad register-calculation input — the Code Preview shows the error instead of the code. It displays a warning with the reason reported by the backend (for example, “Invalid register calculation input: …”), and a banner is shown in the editor highlighting the configuration error. Fix the flagged settings and the code is regenerated automatically. If code generation is not available for the selected processor, an informational message is shown in the preview instead.

6. Working with GitHub Copilot (experimental)#
The DDR Tool registers a
@ddrchat participant in GitHub Copilot Chat, allowing you to drive your device setup directly from the chat panel.Natural-language requests are interpreted with deterministic pattern matching, so the results are consistent and do not depend on the language model.
Interaction Modes
Mode |
Command |
Description |
|---|---|---|
Guided Wizard |
|
Step-by-step configuration (processor, memory type, part number, preset) with clickable follow-up buttons |
Status |
|
Show the current selections and active editor context |
Clear |
|
Reset all selections and session state |
Natural Language |
|
Set processor, memory type, part number, or preset using plain English |
Parameter Edits |
|
Propose edits to configuration parameters, then apply them with an Apply Changes button |
Guided wizard — type @ddr /wizard and follow the clickable buttons:

Natural language examples:
@ddr set processor to MX943
@ddr change memory type to LPDDR5
@ddr select part number MIMX9506xxxxN
@ddr load preset LPDDR5_EVK_19x19_6400MTs
@ddr set frequency to 3200 MT/s
@ddr enable write leveling
@ddr set processor to MX943 and memory type to LPDDR4, then show status
Applying parameter edits — when you request a parameter change (for example, @ddr set data rate to 4000 MT/s or @ddr enable inline ECC), the chat proposes the change against the selected preset. If the value is valid, click Apply Changes to apply it. You must have a processor, memory type, and preset selected first.
Note: Code generation and validation are not available from chat. Use the Code Generation and Tests panels in the sidebar for those operations.
7. Board detection#
Connect your NXP MPU board to your development machine.
Use the “Refresh current connection” button in the Connection panel to detect a connected board.

Choose the appropriate COM port in case multiple boards are connected.
Select the USB HID index when required for the target.
The connection icon changes to indicate that the board is connected.
In the Select Connection section, use Test Connection to verify that the tool can communicate with the connected target. The Tests step becomes available only after this connection test passes.

8. Validate configuration by executing tests on the target#
The Tests step is unlocked only after the connection test in the Select Connection section passes.
Configure test parameters:
Click the selected test to open the Test Configuration panel.
Modify test settings and parameters as needed.
Validation errors are displayed if the selected parameters are not correct.

Pattern Settings:
The tests that write a data pattern to the memory and read it back show a Pattern Settings section in the Test Configuration panel. These tests are BIST-1Write-1Read-Turnaround, BIST-2Write-2Read-Turnaround, BIST-4Write-4Read-Turnaround, and Write-Read-Compare.
The section contains:
Pattern Mode: selects which pattern the test writes.
The pattern, shown as a grid of 32-bit words. Each word has its own field, with its index (0, 1, 2, …) next to it. The number of words depends on the test (for example, 10 words for the BIST tests and 16 words for Write-Read-Compare).
A hint that states which pattern is used by the run.
A Copy pattern to clipboard button next to the pattern label. It copies the pattern in the
[0x..., 0x...]format. The tooltip changes to “Copied!” after the copy.
Mode |
Pattern written by the test |
Hint |
|---|---|---|
Default |
The default pattern of the test, which you can edit word by word. |
“The default pattern below is written and read back on every run.” |
Random |
A random pattern with the same number of words. It is generated by the tool and shown read-only. |
“The random pattern below is written and read back on every run. Use Regenerate for a new one.” |
The default mode is Default. A test saved before the pattern modes were available also opens in Default mode.
Default mode:
The pattern is shown as Default Pattern and you can edit each word:
Enter each word as a 32-bit hexadecimal value, for example
0xAAAAAAAA. An empty field shows the0x00000000placeholder.When a field loses focus, the word is written in the fixed-width form, so all words line up. For example,
ffor0xffbecomes0x000000FF.If the pattern is not valid, the validation error “Invalid pattern! Use up to 16 comma-separated 32-bit hex values in brackets, e.g. [0xAAAAAAAA, 0x55555555].” is shown, and the test cannot be run until you correct the pattern.

Random mode:
In Pattern Mode, select Random. The tool generates a random pattern right away, with the same number of words as the default pattern, and shows it as Random Pattern.
The random pattern is read-only. The same random pattern is written on every run, until you generate a new one. Because the pattern does not change between runs, you can run the test again with the same pattern, for example to reproduce a failure.
To generate a new pattern, click Generate a new random pattern (the refresh button next to the Random Pattern label). The new pattern replaces the previous one, and the next run uses it.

Notes:
The random pattern is saved with the test, so it is shown again when you open the test later.
The random pattern that is written is also added to the test log (for example, “Random test pattern: [0x1A2B3C4D, …]”), so you can find the pattern of a failing run.
If a test is in Random mode but has no valid random pattern (for example, a test saved before), a new random pattern is generated when you open or run the test.
When you switch from Random back to Default, the default pattern is used again. The random pattern is kept, so it is shown again if you select Random later.
While a test is running, Pattern Mode, the pattern fields, and the Generate a new random pattern button are disabled.
Execute test:
Tests cannot be executed while the configuration has validation errors; resolve all flagged fields so the configuration is valid before running a test.
Click the Start button to start the test execution.
To run several tests one after the other, use Run all tests or Run selected tests (see Running all tests or selected tests).
While the test is running, an In progress status indicator is displayed next to the test. The test cannot be started again until it finishes or is cancelled.

The pass / fail status icon is displayed after the test finishes executing.

The test result is also displayed in the Test Result panel and a notification lets you open the log or the test log location.

Execute or cancel a test from the Test Configuration / Test Result view:
The Test Configuration / Test Result view has its own Run Test and Cancel Test buttons. Use them to run or cancel the test from inside this view, without going back to the Run or Cancel buttons in the Tests side panel.
Click Run Test to start the test with the parameters set in the view.
While the test is running, click Cancel Test to stop it.
The test status and results are updated in the same view, so you can change the parameters and run the test again without leaving it.

Cancel a running test:
While a test is running, click Cancel Test in the Tests side panel or in the Test Configuration / Test Result view to stop the current execution. The test status is reported as cancelled.
Running all tests or selected tests:
You can run several tests in one test session instead of starting each test separately. The tests run one after the other, and each test runs in the same way as when you start it with its own Run button. The buttons for a test session are in the header of the Tests section:
Button |
Description |
|---|---|
Run all tests |
Runs every test of every scenario. The tooltip shows the number of tests, for example “Run all tests (12)”. |
Select tests to run |
Turns test selection on, so you can select the tests to run. Click the button again (Exit test selection) to turn test selection off. |
Run selected tests |
Shown instead of Run all tests when test selection is on. Runs only the selected tests. The tooltip shows the number of selected tests, for example “Run selected tests (3)”. |
Stop test session |
Shown instead of the run button while a test session is running. Stops the running test and the rest of the session. |
The run buttons are disabled until the board is connected and the validation server is running. While the buttons are disabled, their tooltip shows “The test can run once the validation server is up and the board is connected”.

Run all tests:
Click Run all tests in the header of the Tests section.
The tool runs all tests of all scenarios, scenario by scenario, in the order in which they are listed. The current test selection is not used.
Run selected tests:
Click Select tests to run in the header of the Tests section. A checkbox is shown next to each test.
Select the checkboxes of the tests that you want to run. You can select tests in several scenarios: click a scenario card to show its tests, and then select the tests in that scenario.
The number of selected tests is shown next to the Tests label (for example, “5 selected”).
Each scenario card shows how many of its tests are selected (for example, “2/7”).

Click Run selected tests. The button is disabled when no test is selected.
The selected tests run scenario by scenario, in the order in which they are listed in the Tests section. The order in which you selected the tests is not used.
Selecting a test does not change its status, and running a test does not change the selection. When you turn test selection off, the selection is kept, so you can turn it on again later and run the same tests. The selection is cleared when you reset the configuration.
While a test session is running:
The list of tests to run is fixed when the session starts. The checkboxes and the Select tests to run button are disabled until the session ends.
The status of each test is updated in the Tests list while the test runs, in the same way as for a single test (In progress, then the pass/fail status).
The configuration stays locked for the whole session, including between tests. A lock icon and the hint “Disabled while a test is running” are shown, and you cannot start another test until the session ends.
A test that has configuration errors is skipped, and the session continues with the next test.
Click Stop test session (or Cancel Test on the running test) to stop the session. The running test is cancelled, and the remaining tests of the session are not run.

8.1. ODT and driver strength tests#
The Optimization Scenario includes two tests, Read ODT and driver and Write ODT and driver, that help you choose the termination (ODT) and driver strength settings that work best on your board. Each test shows its results in a table:

How the test works:
Each cell of the table is one combination of a row value and a column value, and it runs as a separate test.
For each cell, the tool applies the two values to your current configuration, regenerates the PHY initialization data, and then runs the memory stress test on the target.
The cells run one at a time, row by row. The rest of your configuration (the selected preset and your changes) is the same for every cell. Only the two swept values change.
The test reports an overall pass when all cells have been executed, even if some cells fail. The failing cells are expected: they show where the signal margins are not good enough. The useful result is the pass/fail map.
Result table:
When the test starts, the Test Result panel shows the result table. The cells fill in while the test runs:
A summary line above the table shows the progress (for example, “Running combination 5 of 24”) and, when the test finishes, the number of passing combinations (for example, “14 of 24 combinations passed”).
The cell that is currently running shows an animated indicator, and its row and column headers are highlighted.
The following figure shows the result table while the test runs. The cells that have already run show their Pass or Fail status, the current cell shows the running indicator with its row and column headers highlighted, and the remaining cells are still empty.

Hover over a cell to see its tooltip with the row value, the column value, and the cell status.
The legend below the table shows how many cells have each status:
Status |
Meaning |
|---|---|
Pass |
The test of this cell ran and passed. |
Fail |
The test of this cell ran and failed. |
Cancelled |
The test of this cell was running when the test was cancelled. |
Skipped |
The test of this cell did not run because the test was cancelled before it. |
Not run |
The test of this cell has not run yet. |
The following figure shows a result table with cells in different states (Pass, Fail, Cancelled, Skipped, and Not run), together with the legend and the number of cells in each state.

If you cancel the test, the cells that have already finished keep their results. The cell that was running is marked Cancelled and the remaining cells are marked Skipped.
Selecting the best passing cell:
The passing cells form one or more passing areas on the map. Do not select a cell just because it passes. A cell on the edge of a passing area has little margin, and it can fail with small changes in temperature or voltage, or from one board to another. To select the setting for your design:
Find the largest continuous passing area in the table.
Select a cell near the center of that area, ideally a cell whose neighbors (above, below, left, and right) also pass.
If several cells are equally good, select the one that matches your design priorities. Higher impedance values usually reduce power consumption, while lower values usually give stronger signals on longer or heavily loaded traces.
The following example shows a possible result of the Read ODT and driver test. The values are for illustration only. Your result depends on your board.

In this example, the cells in the 80, 60, and 48 ohm columns pass for all PHY ODT values. The cell PHY ODT = 60 ohm, DRAM driver strength = 60 ohm is a good choice because all the cells around it also pass. The cells in the 240 ohm column and the corners of the table fail, so values near them have little margin.
Applying the selected values:
Running the test does not change your configuration. After the test finishes, you can apply the values of a cell to the configuration directly from the result table, or you can enter them in the configuration editor manually.
Apply the values of a cell from the result table:
Wait until the test finishes. You can select the cells only when the test is not running and at least one cell has a result. The cell tooltip then ends with “click to apply these settings”.
Click the cell that you want to use. The cell is highlighted, and the Selected combination panel opens below the legend.
The panel shows:
The status of the cell (Pass, Fail, Cancelled, Skipped, or Not run).
The settings of the cell, each with its name and value (for example, the PHY ODT and the DRAM driver strength). Hover over a setting to see the name of the configuration parameter that is changed.
A warning when the cell did not pass:
For a Fail cell: “These settings failed the test. Applying them is not recommended.”
For a Cancelled, Skipped, or Not run cell: “These settings were not tested. Applying them is not recommended.”

Click Apply to configuration. The tool writes the values of the cell to the memory-side and the PHY-side fields of the open configuration, in one step. The message in the panel shows the result:
Message |
Meaning |
|---|---|
Applying the settings… |
The values are being written to the configuration. |
The settings were applied to the configuration. |
The values were applied. The button changes to Applied. |
The configuration already uses these settings. |
The configuration already has these values, so nothing was changed. The button changes to Applied. |
The settings could not be applied. |
The values were not applied, for example, because the configuration editor is not open or a test is running. |
To close the panel without applying the values, click Close (X) in the panel, click the selected cell again, or press Esc.

Notes:
The configuration editor of the preset must be open, because the values are applied to it. They are validated, and the code is generated again, in the same way as when you edit the fields manually.
The values cannot be applied while a test or a test session is running.
If the configuration does not have a setting of the cell, the setting is not applied, and the warning “The configuration does not have these settings: …” is shown with the setting names.
Applying the values is a configuration change. The results of the tests that ran with the previous configuration are cleared, and the Test Result view is closed. Run the tests again to check the new values.
The configuration is marked as modified. Save it to keep the new values (see Saving configuration changes).
When you run the test again, the selected cell is cleared.
Enter the values manually:
You can also enter the values of the selected cell in the configuration editor manually. Each cell combines one value for the memory (DRAM) side and one value for the PHY side, so you set the values in two places:
Memory side: enter the DRAM value of the selected cell in the memory side fields.

PHY side: enter the PHY value of the selected cell in the PHY side fields.

For the cell selected in the example above, set the DRAM driver strength to 60 ohm on the memory side and the PHY ODT to 60 ohm on the PHY side.
Note: To find these fields quickly, type part of the field name in the Filter settings box of the configuration editor toolbar.
Run the Read ODT and driver test and the Write ODT and driver test separately, and apply the values that you select from each table. Because applying the values from one table clears the test results, run the second ODT test after you apply the values from the first one. To confirm the new settings, save the configuration and run the other tests again.
8.2. Diagnostics (VTSA) eye tests#
The Diagnostics Scenario includes two eye tests, also called VTSA tests. Each test sweeps the sampling delay and the reference voltage (Vref) on the target and measures the data eye of every DQ lane. You can use the results to check how much timing and voltage margin each lane has, and to find the weakest lanes on your board.
Test |
Direction |
What it measures |
|---|---|---|
Diag Rx Eye |
Read (Rx) |
The eye of the data that the PHY receives from the DRAM |
Diag Tx Eye |
Write (Tx) |
The eye of the data that the PHY sends to the DRAM |
Test parameters:
Use Byte Lane to select the byte lane to test, and Bit Lane to select the bit (DQ) lane inside that byte. By default, both are set to All Lanes.

When the test captures all lanes, the result views offer byte and lane selectors. When you restrict the test to one byte lane and one bit lane, the result has only one lane, so the selectors are hidden and the eye diagram shows only the single-lane view.
Test results:
The eye results are displayed only after the test passes. The Test Result panel then shows the Diags Rx Eye Results or Diags Tx Eye Results group. The group contains three sections: Diagnostic Rx/Tx Eye Summary, Eye Diagram, and All Lanes Summary. Each section can be collapsed and expanded.
Summary:
The Diagnostic Rx/Tx Eye Summary section shows the PASS/FAIL verdict of the test and the main values of the measurement.
Worst Width and Worst Height are displayed only when more than one lane was captured.
Note: The trained Vref is not always exactly in the center of the eye. This is normal.
The following figure shows the Diagnostic Rx/Tx Eye Summary section.

Eye diagram charts:
The Eye Diagram section shows the eye of each lane as a heat map, with the delay on the horizontal axis and Vref on the vertical axis. A red cross marks the trained operating point (the delay and Vref selected by training). Hover over the chart to see the delay relative to the trained point, the Vref, and the measured value. Below each eye, the eye width (W, in %UI) and the eye height (H, in V) are displayed. Use View to select how the eyes are displayed:
View |
Description |
|---|---|
Single lane |
The eye of one lane. Select the lane (DQ0, DQ1, …) in Lane. |
Grid |
The eyes of all the lanes of the selected byte, side by side (default view). |
Use Byte to show one byte or all bytes. The views that are available depend on the processor and test.

All Lanes Summary table (worst DQ for width and height):
The All Lanes Summary table lists every lane in the selection. The rows are sorted by eye width, so the lanes with the smallest width are at the top. Use Show to show all bytes or one byte. The table has the following columns:
Column |
Description |
|---|---|
Lane |
The DQ lane (for example, DQ5) |
Byte |
The byte that the lane belongs to |
Width (%UI) |
The eye width |
Left / Right |
The timing margins on each side of the trained point, in %UI |
W Status |
The width status of the lane |
Height (mV) |
The eye height |
Top / Bottom |
The voltage margins above and below the trained point, in mV |
H Status |
The height status of the lane |
The W Status and H Status columns show the following labels:
Label |
W Status |
H Status |
|---|---|---|
FAIL |
The eye width is below 40 %UI. |
The eye height is below 80 mV. |
WORST W |
The lane has the smallest eye width in the selection. |
- |
WORST H |
- |
The lane has the smallest eye height in the selection. |
PASS |
The eye width is at least 40 %UI. |
The eye height is at least 80 mV. |
A failing lane always shows FAIL, even if it is also the worst lane. Below the table, a footer names the worst DQ for width and the worst DQ for height, for example: “Worst width: DQ5 (52.00 %UI) · Worst height: DQ11 (98.4 mV)”. When you select one byte in Show, the worst lanes are recalculated for that byte only.
The following example shows a possible result for one byte. The values are for illustration only.

In this example, all the lanes pass. DQ22 has the least timing margin and DQ7 has the least voltage margin, so they are the first lanes to check if the margins change.
Using the diagnostics results:
If all lanes show PASS, the configuration has enough timing and voltage margin on the tested chip select.
If a lane shows FAIL, or the worst lanes have much smaller margins than the other lanes, check the board routing and the bus mapping of those lanes (see Board bus configuration).
To improve the margins, run the ODT and driver strength tests (see ODT and driver strength tests), apply the new values, and then run the diagnostics tests again to compare the worst width and worst height.
9. Test logging#
The Test execution log is displayed in the DDR Tool for VS Code console that automatically opens at the bottom when a test starts.
Upon test completion, a summary report is generated displaying the overall test results. A notification appears with options to open the log file or log folder.

Note: The summary report of a test run is not the same as the validation report. The validation report sums up the complete validation of the selected preset (see Validation report).
9.1. DDR Tool Logs#
The DDR Tool Logs panel contains the Log Viewer. It collects the tool logs from the extension, the backend, the PHY initialization, and the application running on the target in one place. The panel opens at the bottom of VS Code when the tool starts. To open it again, use the DDR Tool Logs tab in the panel area, or open the Command Palette (Ctrl+Shift+P) and run DDR Tool for VS Code: Show Log Viewer.
Each log entry shows the time, level, source, and message. Entries are colored by level. The status bar at the bottom of the viewer shows the number of displayed entries and the total number of entries, for example, 20 of 1306 entries. The tool keeps the latest 20,000 log entries.

Level:
Select the minimum level to show in the Level list: DEBUG, INFO, WARNING, or ERROR. The viewer shows the entries of the selected level and of the higher levels. For example, WARNING shows the warnings and the errors.
DEBUG is selected by default, so all entries are shown.
Sources:
The Sources check boxes select the sources whose entries are shown:
Extension: messages of the DDR Tool extension.
Backend: output of the tool backend (the validation server).
Target Application: output of the application that runs on the target during a test.
PHY Init: messages of the PHY initialization code generation and of the PHY training on the target.
Clear a check box to hide the entries of that source, or select it to show them again. To show or hide all sources at once, use the All check box.
Search:
Type text in the Search logs box to highlight the matches in the displayed entries. The search is not case-sensitive. The viewer scrolls to the first match, and a counter shows the current match and the number of matches, for example
2 of 15. If nothing matches, the counter shows No results.To go to the next match, click the Next match (down arrow) button or press Enter. To go to the previous match, click the Previous match (up arrow) button or press Shift+Enter. After the last match, the navigation starts again at the first match.
To clear the search, click the Clear search (X) button or press Esc in the search box.
To move to the search box, press Ctrl+F (Cmd+F on macOS) in the viewer.
The search applies only to the entries that the Level and Sources filters show.
Go to top / Go to bottom:
Click Go to top to scroll to the oldest entry that is displayed.
Click Go to bottom to scroll to the newest entry. When the view is at the bottom, it follows new entries as they arrive (live tailing). It stops following when you scroll up, and starts again when you scroll back to the bottom.
Pause / Resume log tailing:
Click Pause log tailing to stop the display of new entries, for example to read the log during a test. A banner shows Tailing paused and the number of new entries received since the pause. The tool still records the new entries while the view is paused.
Click Resume log tailing to show the new entries and to follow the newest entries again.
Clear log view:
Click Clear log view to delete all log entries. This also clears the log history that the tool keeps for export, so export the logs first if you want to keep them.
Export logs (save):
Click Export logs (the save icon) and select the logs to export:
Complete log history: all the entries that the tool keeps.
Filtered logs: the entries that match the current Level and Sources filters.
Logs for a category: the entries of one source. Select the source in the list, which shows the number of entries of each source.
Logs within a time range: the entries between a start time and an end time. Enter each time as
YYYY-MM-DD hh:mm:ssorhh:mm:ss. The end time cannot be before the start time.
Then select the location and the name of the file in the save dialog. By default, the file is saved in the workspace folder (or your home folder) as a .log file named with the scope and the time, for example logs_filtered_20261124_164500.log. When the export is complete, a notification shows the number of exported entries and an Open button that opens the file in the editor. If there are no entries to export, a message tells you so.
The tool remembers the Level, Sources, and Search settings of the viewer while VS Code is open.
10. Validation report#
The DDR Validation Report shows in one view how far the validation of the selected preset has gone and what the results are. It sums up the DDR configuration, the PHY settings, the test results, the ODT mapping, the eye diagrams, and the test logs, and gives an overall Final Result. You can export the report as a PDF file or as an HTML file, for example to share it or to keep it with your board records.
10.1. Opening the report#
You can open the report in any of these ways:
Click the Reports entry in the Welcome panel.

Click the View Report button in the Tests section.

Open the Command Palette (Ctrl+Shift+P) and run DDR: View Validation Report.
The report opens in an editor tab named DDR Validation Report. If the report is already open, its tab comes to the front. The report is live: while it is open, it updates automatically when the configuration changes, when the code is generated, when a test starts or ends, and when each ODT combination finishes. You do not have to refresh it.
10.2. Report layout#
The report contains the following parts, from top to bottom:
Header: the title, the current selection (processor / memory type / part number / preset), the time when the report was generated, and the Export Report button. If no preset is selected, the header shows “No processor and memory preset selected”.
Final Result card: the overall result of the validation.
Area cards: one card for each validation area, in a grid.
Each card has a title, a status badge, and a one-line summary. Click the card header to show or hide the details of the card. A card that has nothing to show yet displays “No details yet.” when you expand it.

Each card and each item in a card shows one of the following status badges:
Status |
Meaning |
|---|---|
Not executed |
Nothing has run yet. |
Running |
A task of the card is running, for example a test or the code generation. |
Partial |
Some tasks are done without failures or warnings, and others are not done yet. |
Complete |
All tasks are done without failures or warnings. |
Warning |
A task ended with a warning, for example a cancelled test. |
Fail |
A task failed. |
10.3. Report cards#
Card |
Content |
|---|---|
DDR Main Configuration |
The selection, the memory configuration settings, the DDR interface pinout, and the configuration errors. |
PHY Main Configuration |
One table for each PHY initialization section, with the parameters and their values. |
Test Results |
A table with every available test, its scenario, and its status. |
ODT Scenario Mapping Results |
One grid for each ODT and driver strength test, with the result of each combination. |
Eye Diagrams |
For each diagnostics (VTSA) test, a lane table and a small eye outline for each lane. |
Logs |
The last lines of the latest saved log of each test. |
Final Result |
The overall result, and the status and summary of every other card (see Final Result). |
DDR Main Configuration:
When expanded, the card shows:
Selection: the processor, board, memory type, part number, preset, and firmware version.
Memory configuration: the visible memory configuration settings and their values, grouped by section.
DDR Interface Pinout - DQ mapping: a table with one row for each PHY DQ pad (DQ00 to DQ15) and one column for each channel. Each cell is the DRAM DQ signal wired to that pad. Channel B is not shown for a single-channel memory.
DDR Interface Pinout - CA mapping: the same table for the CA pads. It is shown only if the board remaps the CA pins.
Errors: the configuration and pinout errors, and the code generation error, if there are any.
In the pinout tables, a DRAM signal that is wired to more than one pad of a channel is highlighted, and its rows are marked as failed.

PHY Main Configuration:
The card shows one table for each PHY initialization section, with the Parameter and Value columns. The summary gives the number of parameters and sections, for example “48 PHY parameters in 3 section(s)”. The status is Complete if the PHY settings have no errors, Fail if they have errors (the errors are listed above the tables), and Warning if the preset has no PHY initialization configuration.
Test Results:
The card shows a table with the Test, Scenario, and Status columns for every test that is available for the memory. Each row has its own status badge:
A test that passes is complete. A successful ODT or diagnostics run is listed as Executed, and is also complete.
A test that fails is a failure.
A test that is cancelled or invalid is a warning.
The card is Complete only when every test is complete. While a test runs, the summary shows its name and the progress, for example “Running Write-Read-Compare (3 of 12 done)”. When tests have run, the summary shows the result, for example “12 of 12 test(s) done: 1 failed, 0 cancelled or invalid”.

ODT Scenario Mapping Results:
The card shows one grid for each ODT and driver strength test (see ODT and driver strength tests). The grid has the same rows and columns as the result table of the test, and each cell shows the status of that combination. Hover over a cell to see its status. The title of each grid gives the number of passing combinations, for example “Read ODT and driver - 14 of 24 combinations passed”.
Failing combinations are expected, because the table maps the working window. A table is complete when it has run and at least one combination passes. It fails if no combination passes, and it is a warning if the run was cancelled. The card is Partial while only some of the ODT tables have run.

While an ODT test runs, the grid is filled in live, the current combination is shown as running, and the summary shows the progress, for example “Read ODT and driver: running combination 5 of 24”.
Eye Diagrams:
The card shows the results of the diagnostics (VTSA) eye tests (see Diagnostics (VTSA) eye tests). A note at the top states the pass rule: a lane passes when its eye is at least 40 %UI wide and 80 mV high. For each diagnostics test, the card shows:
A lane table with the Lane, Byte, Width (%UI), and Height (mV) columns. Lanes with the worst width and the worst height are highlighted. A note under the table names the worst lanes, for example “Highlighted: worst width 67.19 %UI (DQ19), worst height 113.1 mV (DQ27). Failing lanes are shown in red.”.

An eye outline for each lane. The outline shows the open eye over the scanned range: the strobe delay goes from left to right, the Vref goes from bottom to top, and a cross marks the trained point. Each outline shows the lane, the eye width and height (for example “W 59.38 %UI, H 143.4 mV”), and the scanned range (for example “Delay 179-250 UI, Vref 0.019-0.274 V”). If the eye is closed at the trained point, the outline shows “No open eye at the trained point”.

The summary gives the worst values, for example “32 of 32 lanes pass. Worst width 67.19 %UI (DQ19), worst height 113.1 mV (DQ27)”. The card fails if a lane fails, and it is a warning if a diagnostics run ended without eye data.
Logs:
The card shows the last 30 lines of the latest saved log of each test. The title of each log gives the test name, the number of lines, and the time of the run. Click Open Log to open the full log file in the editor. If the log file cannot be found, the card shows the warning “No saved log was found for this test.”
The status is Complete when every test has a saved log, Partial when only some tests have a log, and Warning when a log contains errors.

10.4. Final Result#
The Final Result card combines the status of the other cards:
Fail if a card fails. The summary names the cards that failed, for example “Failed: Test Results”.
Running while a test or the code generation is running.
Warning if a card ended with a warning. The summary names those cards.
Partial if some cards are not finished yet. The summary names those cards, for example “Incomplete: Eye Diagrams, Logs not finished yet”.
Complete (“All checks completed.”) when every card is complete.
When expanded, the card lists the status and summary of every other card. A card that does not apply to the selected memory (for example, the ODT card when the memory has no ODT tests) does not change the final result.

10.5. Excluding a card from the report#
Each card, except Final Result, has an eye icon in its header. Click the icon to leave the card out of the final result and of the exported report, for example when an area does not apply to your board.
The excluded card stays in the view, greyed out, with an Excluded badge and the hint “Not included in the final result or in the exported report.”.
In the Final Result card, the excluded card is marked Excluded, and its status no longer changes the final result.
Click the eye icon again to include the card.
When you close the report, all excluded cards are included again.
If you exclude every card, the final result shows “Every card is disabled: nothing to check.”

10.6. Exporting the report#
Click Export Report in the report header. You can also run DDR: Export Validation Report from the Command Palette. In this case, the report does not have to be open.
In the save dialog, select the file type: PDF document (default) or HTML report. The default file name contains the processor and the preset, and ends with
_validation_report.pdf. The default folder is the first workspace folder, or your home folder if no workspace is open.

Click Export Report. When the file is written, the notification “Validation report exported to
” appears. Click Open to open the file.

If the file cannot be written, the error “Could not export the validation report: …” appears.
The exported report contains the same information as the live view, with all cards expanded:
The header lists the excluded cards (“Not included: …”), so a reader knows that they were left out on purpose.
The footer shows the version of the DDR Tool that generated the report.
The extension generates the PDF file, so no browser is needed. Its pages are numbered (“Page 1 of 4”).
The HTML file is a single file that you can open in any browser. It contains no scripts and loads no external resources.
11. Import configuration#
The Import button allows you to load a previously saved configuration.

12. Reset configuration#
The Reset Configuration button clears the currently loaded configuration and returns the sidebar to processor selection.
If there are unsaved changes, the tool prompts you to confirm before discarding them and closing the open configuration editor.

Basic workflow#
Start Tool → Select Processor → Select Memory Type → Select Part Number → Load Preset → Configure Memory Settings → Board Detection → Validate Configuration by Executing Tests → Review and Export Validation Report → Save Configuration
User interface overview#
The tool interface is a single unified panel that guides you through three progressive steps: Configuration, Connection, and Tests. Later steps unlock as earlier ones are completed (for example, the Tests step becomes available after the connection is verified), and completed sections collapse into a summary bar so you can keep an overview of your selections.
Main interface components#
Welcome Panel#
The Welcome Panel is the starting point for toolchain management and initial setup. Before the toolchain is installed (and after the notice is accepted), it offers the Install Toolchain action. After the toolchain is installed, the panel shows four entries:
Manage Toolchains: install, uninstall, reset, or update the toolchain. A badge indicates when an update is available.
Reports: opens the DDR validation report (see Validation report).
Documentation: opens the online DDR Tool documentation in your browser.
View Disclaimer: reopens the DDR Tool Notice for review at any time.
DDR Configuration Panel#
The DDR Configuration panel is the main workspace. It contains three subsections that unlock progressively:
Select Configuration: choose the processor, memory type, part number, and preset, and open the configuration editor to adjust DDR settings. Import, Save, and Reset Configuration actions are available here. The generated C code is shown in the Code Preview alongside the settings and is regenerated automatically as the configuration changes.
Select Connection: detect the connected board, choose the COM port and USB HID index, and run Test Connection to verify communication with the target.
Tests: run memory tests on the connected target (an individual test, all tests, or the selected tests), cancel a running test or test session, and review pass/fail results. The View Report button opens the validation report. This subsection becomes available only after the connection test passes.
The Select Configuration and Select Connection subsections can each be summarized or expanded. When a step is completed it automatically collapses into a summary bar that shows your current selections; click the summary bar (or its expand/collapse control) to expand the subsection again and change your choices, and collapse it back to a summary when you are done. This lets you keep an overview of all steps while working in one section at a time.

Configuration Editor#
Opened from the Select Configuration subsection, the Configuration Editor is where you edit the DDR settings (Memory Configuration, DDR Controller, and board bus mapping). It provides real-time, field-level validation and a toolbar for working with the settings (reset to default, validation status, filter, and expand/collapse all).
Code Preview#
The Configuration Editor shows a Code Preview alongside the settings that display the C source generated from the current configuration. The code is generated automatically and regenerated whenever the configuration changes. The preview supports change indicators, a diff (changes-only) view, structure folding, manual editing, exporting the code to a file, and shows an error when the configuration cannot be generated.
Validation Report#
The DDR Validation Report opens in an editor tab from the Reports entry in the Welcome panel, the View Report button in the Tests section, or the Command Palette. It shows one card for each validation area, each with a status and a summary, and an overall Final Result. The report is updated automatically, and you can export it as a PDF or HTML file (see Validation report).
DDR Tool Logs#
The DDR Tool Logs panel at the bottom of VS Code contains the Log Viewer, which shows the logs of the extension, the backend, the target application, and the PHY initialization. You can filter the logs by level and source, search them, go to the top or bottom of the log, pause live tailing, clear the logs, and export them to a .log file (see DDR Tool Logs).
Troubleshooting#
This chapter contains known problems and recommended solutions.
Issue: tool does not start#
Symptoms: Extension loads but the tool interface does not appear.
Solutions:
Restart VS Code
Check if Python environment is properly installed
Run “Manage Toolchain” and Reset Toolchain
Reinstall Toolchain using “Install Toolchain” button
Check the DDR Tool Logs panel (set Level to ERROR or WARNING) and the VS Code output panel for error messages
Issue: device is not recognized#
Symptoms: Board does not appear in the connection panel.
Solutions:
Use a supported operating system
Verify the board is properly connected via USB
Update the extension to the latest version
Check system requirements
Known issues and limitations#
This chapter contains limitations and possible workarounds.
Current limitations#
Operating system support:
Supported on Windows 11 (64-bit) and Ubuntu 24.04 / 26.04 (64-bit)
macOS support may be available in future releases
Feature limitations:
When the Import configuration feature is used, the tool does not import changes made to the configuration.
Workarounds#
Unsupported operating systems#
Use a supported operating system or a virtual machine
Check the documentation for OS support updates
Additional device support#
Check for extension updates regularly
Contact NXP support for roadmap information
References#
Documentation:
i.MX 91 reference manual
i.MX 93 reference manual
i.MX 93W reference manual
i.MX 937 reference manual
i.MX 943 reference manual
i.MX 95 reference manual
i.MX 952 reference manual
Online resources:
Technical support:
Revision history#
Document ID |
Release date |
Description |
|---|---|---|
UG10486 v.2.0 |
30 October 2026 |
Updated for 26.11. |
UG10486 v.1.0 |
30 September 2026 |
Initial version. |
Note about the source code in the document#
Example code shown in this document has the following copyright and BSD-3-Clause license:
Copyright 2026 NXP Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Legal information#
Definitions#
Draft — A draft status on a document indicates that the content is still under internal review and subject to formal approval, which may result in modifications or additions. NXP Semiconductors does not give any representations or warranties as to the accuracy or completeness of information included in a draft version of a document and shall have no liability for the consequences of use of such information.
Disclaimers#
Limited warranty and liability — Information in this document is believed to be accurate and reliable. However, NXP Semiconductors does not give any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information. NXP Semiconductors takes no responsibility for the content in this document if provided by an information source outside of NXP Semiconductors.
In no event shall NXP Semiconductors be liable for any indirect, incidental, punitive, special or consequential damages (including - without limitation - lost profits, lost savings, business interruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory.
Notwithstanding any damages that customer might incur for any reason whatsoever, NXP Semiconductors’ aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the Terms and conditions of commercial sale of NXP Semiconductors.
Right to make changes — NXP Semiconductors reserves the right to make changes to information published in this document, including without limitation specifications and product descriptions, at any time and without notice. This document supersedes and replaces all information supplied prior to the publication hereof.
Suitability for use — NXP Semiconductors products are not designed, authorized or warranted to be suitable for use in life support, life-critical or safety-critical systems or equipment, nor in applications where failure or malfunction of an NXP Semiconductors product can reasonably be expected to result in personal injury, death or severe property or environmental damage. NXP Semiconductors and its suppliers accept no liability for inclusion and/or use of NXP Semiconductors products in such equipment or applications and therefore such inclusion and/or use is at the customer’s own risk.
Applications — Applications that are described herein for any of these products are for illustrative purposes only. NXP Semiconductors makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification.
Customers are responsible for the design and operation of their applications and products using NXP Semiconductors products, and NXP Semiconductors accepts no liability for any assistance with applications or customer product design. It is customer’s sole responsibility to determine whether the NXP Semiconductors product is suitable and fit for the customer’s applications and products planned, as well as for the planned application and use of customer’s third party customer(s). Customers should provide appropriate design and operating safeguards to minimize the risks associated with their applications and products.
NXP Semiconductors does not accept any liability related to any default, damage, costs or problem which is based on any weakness or default in the customer’s applications or products, or the application or use by customer’s third party customer(s). Customer is responsible for doing all necessary testing for the customer’s applications and products using NXP Semiconductors products in order to avoid a default of the applications and the products or of the application or use by customer’s third party customer(s). NXP does not accept any liability in this respect.
Terms and conditions of commercial sale — NXP Semiconductors products are sold subject to the general terms and conditions of commercial sale, as published at https://www.nxp.com/profile/terms, unless otherwise agreed in a valid written individual agreement. In case an individual agreement is concluded only the terms and conditions of the respective agreement shall apply. NXP Semiconductors hereby expressly objects to applying the customer’s general terms and conditions with regard to the purchase of NXP Semiconductors products by customer.
Export control — This document as well as the item(s) described herein may be subject to export control regulations. Export might require a prior authorization from competent authorities.
Suitability for use in non-automotive qualified products — Unless this document expressly states that this specific NXP Semiconductors product is automotive qualified, the product is not suitable for automotive use. It is neither qualified nor tested in accordance with automotive testing or application requirements. NXP Semiconductors accepts no liability for inclusion and/or use of non-automotive qualified products in automotive equipment or applications.
In the event that customer uses the product for design-in and use in automotive applications to automotive specifications and standards, customer (a) shall use the product without NXP Semiconductors’ warranty of the product for such automotive applications, use and specifications, and (b) whenever customer uses the product for automotive applications beyond NXP Semiconductors’ specifications such use shall be solely at customer’s own risk, and (c) customer fully indemnifies NXP Semiconductors for any liability, damages or failed product claims resulting from customer design and use of the product for automotive applications beyond NXP Semiconductors’ standard warranty and NXP Semiconductors’ product specifications.
HTML publications — An HTML version, if available, of this document is provided as a courtesy. Definitive information is contained in the applicable document in PDF format. If there is a discrepancy between the HTML document and the PDF document, the PDF document has priority.
Translations — A non-English (translated) version of a document, including the legal information in that document, is for reference only. The English version shall prevail in case of any discrepancy between the translated and English versions.
Security — Customer understands that all NXP products may be subject to unidentified vulnerabilities or may support established security standards or specifications with known limitations. Customer is responsible for the design and operation of its applications and products throughout their lifecycles to reduce the effect of these vulnerabilities on customer’s applications and products. Customer’s responsibility also extends to other open and/or proprietary technologies supported by NXP products for use in customer’s applications. NXP accepts no liability for any vulnerability. Customer should regularly check security updates from NXP and follow up appropriately.
Customer shall select products with security features that best meet rules, regulations, and standards of the intended application and make the ultimate design decisions regarding its products and is solely responsible for compliance with all legal, regulatory, and security related requirements concerning its products, regardless of any information or support that may be provided by NXP.
NXP has a Product Security Incident Response Team (PSIRT) (reachable at PSIRT@nxp.com) that manages the investigation, reporting, and solution release to security vulnerabilities of NXP products.
NXP B.V. — NXP B.V. is not an operating company and it does not distribute or sell products.
Trademarks#
Notice: All referenced brands, product names, service names, and trademarks are the property of their respective owners.
NXP — wordmark and logo are trademarks of NXP B.V.